A.A.R.G. rebreather diving standards.
Copyright Rodney Nairne and the AARG. Last revised 22nd February 1998.
A.A.R.G. standards: background definitions.
Back to top
FO2 = Fraction of Oxygen in a gas mixture.
Partial Pressure =
The pressure exerted by any constituent gas in a mixture; the most
significant measurement with respect to the physiochemical and
physiologic behavior of a gas. As described by Dalton’s law, the total
pressure of a gas mixture is the arithmetic sum of all the individual
partial pressures of the constituent gases.
PO2 = Partial pressure of Oxygen.
C02 = Carbon Dioxide.
Loop = The loop describes the counterlungs, breathing hoses, C02 absorption
canister/system and mouthpiece with upsteam and downstream check valves.
Basically all gas filled parts of a rebreather that contains gas
rebreathed by the diver.
Flushthru = technique of venting all the gas in the loop and the replacement
of this gas from a high pressure gas cylinder. A common procedure used
especially but not exclusively by semi-closed circuit divers.
Setpoint = the chosen operating PO2 of fully closed circuit rebreathers.
Hypoxia = physiological symptoms precipitated by insufficient oxygen.
Hyperoxia = physiological symptoms of excess oxygen.
Hypercapnia = physiological symptoms of increased carbon dioxide tension in
lung gas and blood usually encountered in rebreathers due to scrubber
failure/exhaustion and the resultant elevated CO2 in the breathing loop.
Scrubber = the carbon dioxide absorbent canister, a common component in all
self contained rebreathers.
Mixed gas = in relation to rebreathers any gas mix containing >0 and <100%
oxygen, the remainder of the gas mix made up of any single or combination
of inert gas. Note air is classified as mixed gas as the FO2 in the loop
rarely equals FO2 in diluent supply gas.
For the purposes of this standard, rebreathers will be distinguished as one
of 2 types by the following classifications:
Semi closed circuit
Semi closed is defined as a mixed gas rebreather where the metabolised
oxygen is replaced via a source of mixed gas. Designed to operate below
the safe depth of pure oxygen rebreathers. Gas is pre-mixed in high
pressure cylinders with oxygen levels to suit the depth of the dive.
Fully closed circuit
Fully closed is defined as a rebreather in which the metabolised oxygen is
replaced from a source of pure oxygen. Designed for depths exceeding the
safe depth of pure oxygen diving, a source of diluent gas is used to keep
the PO2 within life support range at any depth. The monitoring/control of
oxygen may be either electronic, which invariably involves 3 oxygen
sensors, or cryogenic control physical gas laws.
Fully closed rigs have relatively stable PO2 in the loop, i.e. a variable
F02 which decreases in direct and inverse proportion to increased absolute
pressure. This is in contrast to semi-closed units in which the PO2
increases in direct proportion to depth.
A.A.R.G. has several ratings:
These ratings are unit specific as rebreathers unlike open circuit
equipment may have widely varying safe operating procedures.
RATING REQUIREMENTS
Common Core
Back to top
Common core theory and practice requirements, semi closed and fully closed
rating.
Theory, common core
the diver must demonstrate a sound understanding of the:
- effects of oxygen, both hypoxia and hyperoxia, including PO2 life support
ranges.
- rate of oxygen metabolism in divers
- calculation of the duration of CO2 absorbent
- variables that effect canister duration
- disadvantages of using nitrox supply gas in rebreathers, especially at
depths exceeding 20 meters, including ventilitory requirements of the
diver, inert gas narcosis, decompression and thermal considerations and
canister efficiency.
- physiological effects of elevated CO2 and the ramifications for the
rebreather diver.
- physiological effects of hypoxia and hyperoxia including warning signs
- planning for adequate bailout to the surface, including all required
decompression stops
- reasons why an OC second stage is required as the 1st option for safety
in the event of a loop flood or scrubber failure.
- inherent difficulties of starting the CO2 absorbing reaction in-water and
it’s implications for divers who have a second rebreather as their only
bailout.
Practice, common core
The diver must demonstrate competency in:
- pre-dive preparation of all equipment.
- pre-dive checks including functioning of check valves, loop integrity via
both positive and negative pressure checks, and scrubber functioning via
pre-diving the loop for a minimum of 5 minutes.
- unit specific pre-dive checks
- in water bubble and leak checks.
- providing adequate buoyancy in the event of a loop flood. This is
simulated by the addition of weight equal to the buoyancy of the loop
volume of the rebreather being used, and where appropriate additional
weight to simulate suit compression due to depth.
- a blue water ascent maintaining a safe ascent rate, and adequate buoyancy
control. This is more difficult on rebreathers as there may be 3 pieces of
equipment that need buoyancy control: the BC, drysuit, and the loop.
- the ability to plan for the bailout requirements of their dive partners,
including any required decompression stops.
- choice of bailout gas(es) to provide a safe ascent to the surface with a
PO2 of no less than 0.16
- re-filling the scrubber to minimise chance of channeling
- accurate record keeping of dive-time on each canister fill.
- cleaning of the unit between dives
Semi-closed circuit specific requirements
Back to top
Note: if the divers rebreather is commercially manufactured the diver must
have completed a manufacturer approved training course specific to that
unit, if available.
Theory, semi closed:
the diver must demonstrate a sound understanding of the:
- calculation of theoretical FO2 in the loop with different flow rates and
supply gases.
- importance of accurate pre-dive flow rate testing for constant mass flow
semi-closed units
- duration extension of CO2 absorption advantage in semi-closed units.
- effects/risk of flow rate reductions caused by foreign particles in the
constant mass flow orifice.
- calculation of equivalent depths, for decompression calculations
Practice, semi closed circuit rating
- For constant mass flow units, the diver must demonstrate competency in
pre-dive flow rate testing. This includes introduction of back pressure
equal to planned diving depth.
- For other types of semi-closed units, such as passive addition systems,
the diver must demonstrate competency in the unit specific pre dive checks
supply gas flow rate.
- the diver must demonstrate a flushthru before any ascent
- in the case of constant mass flow units with fixed intermediate pressure
1st stage regulator, a secondary cylinder with compensated intermediate
pressure 1st stage, and a OC second stage regulator is required for
bailout
Fully closed circuit specific rating requirements:
Back to top
note: if the rebreather has not been manufactured by the diver, a
requirement for this rating is a manufacturer approved training course
specific to that rebreather, if available.
Theory, CC
the diver must demonstrate a sound understanding of the:
- calculation of adequate diluent volume for the depth of the dive
- parameters for choosing a setpoint PO2
- ways to avoid PO2 spikes on descents, part of choice of correct diluent.
The diver must demonstrate an advanced familiarity with:
- partial pressures of gases
- mixed gas decompression theory
- the ramifications of using helium diluent
- the specific unit being dived
- the common causes of death and inherent weaknesses of the make of unit
they are diving, and ways to avoid them.
Practice, CC
- the diver must demonstrate calibration of the oxygen sensors. The sensors
must be calibrated to 1.0, with pure oxygen. If setpoints greater than 1
are used, the sensors must be calibrated at that setpoint using a pressure
pot, or verified using pure oxygen at the relevant depth before descent.
for example if the setpoint is 1.3, verify sensor readings with pure oxygen
at 3msw.
- the diver must show competency in the manufacturers pre-dive checklist,
if applicable.
- demonstrate an adequate loop flushthru with both diluent and oxygen, as
they may differ in procedure due to placement of addition point in the
loop.
- the diver must demonstrate the ability to control the unit in semi-closed
mode, both with the aid of the oxygen sensors, and simulated without
sensors using pre-dive manual addition semi-closed calculations.
Ask the A.A.R.G.