A.A.R.G. rebreather diving standards.

Copyright Rodney Nairne and the AARG. Last revised 22nd February 1998.

A.A.R.G. standards: background definitions.

Back to top

FO2 = Fraction of Oxygen in a gas mixture.

Partial Pressure = The pressure exerted by any constituent gas in a mixture; the most significant measurement with respect to the physiochemical and physiologic behavior of a gas. As described by Dalton’s law, the total pressure of a gas mixture is the arithmetic sum of all the individual partial pressures of the constituent gases.

PO2 = Partial pressure of Oxygen.

C02 = Carbon Dioxide.

Loop = The loop describes the counterlungs, breathing hoses, C02 absorption canister/system and mouthpiece with upsteam and downstream check valves. Basically all gas filled parts of a rebreather that contains gas rebreathed by the diver.

Flushthru = technique of venting all the gas in the loop and the replacement of this gas from a high pressure gas cylinder. A common procedure used especially but not exclusively by semi-closed circuit divers.

Setpoint = the chosen operating PO2 of fully closed circuit rebreathers.

Hypoxia = physiological symptoms precipitated by insufficient oxygen.

Hyperoxia = physiological symptoms of excess oxygen.

Hypercapnia = physiological symptoms of increased carbon dioxide tension in lung gas and blood usually encountered in rebreathers due to scrubber failure/exhaustion and the resultant elevated CO2 in the breathing loop.

Scrubber = the carbon dioxide absorbent canister, a common component in all self contained rebreathers.

Mixed gas = in relation to rebreathers any gas mix containing >0 and <100% oxygen, the remainder of the gas mix made up of any single or combination of inert gas. Note air is classified as mixed gas as the FO2 in the loop rarely equals FO2 in diluent supply gas.

For the purposes of this standard, rebreathers will be distinguished as one of 2 types by the following classifications:

Semi closed circuit

Semi closed is defined as a mixed gas rebreather where the metabolised oxygen is replaced via a source of mixed gas. Designed to operate below the safe depth of pure oxygen rebreathers. Gas is pre-mixed in high pressure cylinders with oxygen levels to suit the depth of the dive.

Fully closed circuit

Fully closed is defined as a rebreather in which the metabolised oxygen is replaced from a source of pure oxygen. Designed for depths exceeding the safe depth of pure oxygen diving, a source of diluent gas is used to keep the PO2 within life support range at any depth. The monitoring/control of oxygen may be either electronic, which invariably involves 3 oxygen sensors, or cryogenic control physical gas laws.

Fully closed rigs have relatively stable PO2 in the loop, i.e. a variable F02 which decreases in direct and inverse proportion to increased absolute pressure. This is in contrast to semi-closed units in which the PO2 increases in direct proportion to depth.

A.A.R.G. has several ratings:

These ratings are unit specific as rebreathers unlike open circuit equipment may have widely varying safe operating procedures.

RATING REQUIREMENTS

Common Core

Back to top

Common core theory and practice requirements, semi closed and fully closed rating.

Theory, common core

the diver must demonstrate a sound understanding of the:

Practice, common core

The diver must demonstrate competency in:

Semi-closed circuit specific requirements

Back to top

Note: if the divers rebreather is commercially manufactured the diver must have completed a manufacturer approved training course specific to that unit, if available.

Theory, semi closed:

the diver must demonstrate a sound understanding of the:

Practice, semi closed circuit rating

Fully closed circuit specific rating requirements:

Back to top

note: if the rebreather has not been manufactured by the diver, a requirement for this rating is a manufacturer approved training course specific to that rebreather, if available.

Theory, CC

the diver must demonstrate a sound understanding of the:

The diver must demonstrate an advanced familiarity with:

Practice, CC

Ask the A.A.R.G.